Modular raised floor systems for datacenters, offices, cleanrooms and much more. Maximum access and flexibility without compromising load capacity or safety.

A raised computer floor, also known as a raised access floor, is a modular floor on adjustable steel pedestals. This creates an accessible space below the floor for data cabling, electrical wiring, cooling, airflow and other technical installations.
The floor panels can be laid with a standard finish, but in offices you can also choose a colour or other finishes such as laminate, carpet or natural stone.
Anomalie supplies, installs and maintains computer floors for offices, datacenters, server rooms, control rooms and technical spaces. Each floor is tailored to the load, installations and functional requirements of the project. In addition to new installations, we specialise in modifications, extensions and repair work on existing computer floors.
Request a quoteModular system that scales with your infrastructure. Easy to extend and adapt, with options for cut-outs and cable routing.
Removable panels can be lifted in seconds for maintenance, extension or reconfiguration. No demolition, no downtime.
A plenum of 25 to 2,000 mm below the floor for structured routing of data, power, cooling, lightning protection and air handling.
Panels precisely finished in laminate, vinyl, carpet or natural stone. No joints or height differences to disrupt ergonomics or appearance.
Dry construction system with no curing time. A complete office floor is delivered in days, not weeks. Ideal for tightly scheduled renovations.
Sound-absorbing tiles and underlay reduce impact noise and improve speech intelligibility, which is essential in open-plan offices.
| Panel type | Chipboard, calcium sulphate, gypsum, glass, perforated ventilation panels, steel encapsulated wood, natural stone |
|---|---|
| Panel size | 600 Γ 600 mm (standard), custom on request |
| Plenum height | 25 β 2,000 mm, adjustable per pedestal |
| Pedestal spacing | 600 Γ 600 mm, adjustable to suit the site |
| Point load | up to 20 kN per point |
| Surface load | up to 35 kN/mΒ² |
| Weight | 6 kg β 24 kg |
| Surface material | Linoleum, HPL laminate, vinyl, steel, carpet, natural stone or perforated (for air supply) |
| Panel thickness | 20.5 mm β 42 mm |
| Sound insulation | 48 dB β 64 dB standard (adjustable) |
| Fire classification | F30 (REI30) β F60 (REI60) |
| ESD option | Antistatic version available |
Our computer floors have a point load of up to 20 kN per point and a surface load of up to 35 kN/mΒ². The exact value depends on the panel type and pedestal spacing. For heavy installations such as UPS systems we recommend a system floor with a steel substructure.
The void below the floor, the plenum, is available from 25 to 2,000 mm and is adjustable per pedestal. This lets us match the height to the amount of cabling, the cooling and the existing height of doors and stairs.
We supply panels in chipboard, calcium sulphate, gypsum, glass, steel-encased wood and natural stone, as well as perforated ventilation panels for air supply. The standard size is 600x600 mm. Finishes include linoleum, HPL laminate, vinyl, steel, carpet and natural stone.
Yes. We extend existing computer floors, create cut-outs for new cabling or cooling and replace damaged panels, regardless of the brand of the floor. Read more about repairs and modifications.
The price depends on the area, floor height, panel type, finish and accessibility of the site. After a short survey we prepare a tailored, no-obligation quote. Request a quote.