Computer floors for datacenters and data halls. Built for controlled airflow and continuous access to cables and installations.

In a datacenter, the raised floor is more than a walkway. The space below the floor, the plenum, carries cold air to the server racks and houses power cables, data cabling and pipework. At the same time, the floor has to carry the weight of full server cabinets.
Anomalie supplies, installs and maintains computer floors for datacenters, server rooms and mobile datacenter units. We tailor every floor to the load, the cooling and the layout of the data hall. For heavy installations such as UPS systems and large cooling units, we supply a system floor for datacenters.
Because a datacenter cannot go offline, we specialise in working in live environments: replacing panels, creating cut-outs and modifying the floor while the servers keep running.
Request a quoteWe install steel frames for the server cabinets to stand on, so the weight goes straight to the subfloor. The panels carry a surface load of up to 35 kN.
Perforated ventilation panels direct cold air exactly to the server racks. We match the plenum height to the required air capacity.
A plenum height of 25 to 2,000 mm for power, data, lightning protection and pipework. Removable panels give direct access, without demolition.
Anti-static panels prevent electrostatic discharge, which can damage sensitive equipment.
Panels with a fire classification from F30 (REI30) to F60 (REI60), matched to the requirements of your building.
We carry out modifications, extensions and repairs while your datacenter stays operational, in phases and in consultation with you.
A datacenter is always changing. We modify existing floors, including those from other brands: moving perforated panels for cooling, making new cut-outs, replacing panels and strengthening the floor for heavier racks.
We do this in a live environment, without your servers going down.
More about repairs and modifications
Anomalie supplied the computer floors for a series of mobile datacenter units. Compact in design, with space for cables and cooling below the floor.
Want to see more? Take a look at our other projects in datacenters, offices and industry.
View all projectsFor most data halls a computer floor with panels on pedestals is sufficient. For heavy loads, such as UPS rooms or large cooling units, choose a system floor with a steel support structure. We advise on the basis of load, grid and installations.
That depends on the amount of cabling and the required airflow. We supply floors with a plenum height of 25 to 2,000 mm, adjustable per pedestal.
Yes. Perforated ventilation panels let cold air flow from the plenum to the server racks. They fit the same grid as the solid panels, so they are easy to relocate.
Yes. We replace panels, create cut-outs for new cabling or cooling and extend the floor while operations continue. Read more about repairs and modifications.